Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 73 of 509
Mod. 0808 2011-07 Rev.2
Select Wireless Network - +WS46
+WS46 - PCCA STD-101 Select Wireless Network
Set command selects the cellular network (Wireless Data Service, WDS) to
operate with the TA (WDS-Side Stack Selection).
Parameter:
<n> - integer type, it is the WDS-Side Stack to be used by the TA.
12 - GSM Digital Cellular Systems (GERAN only)
22 UTRAN only
25 3GPP Systems (GERAN and UTRAN and E-UTRAN) (factory default)
28 E-UTRAN only
29 GERAN and UTRAN
30 GERAN and E-UTRAN
31 UTRAN and E-UTRAN
NOTE: <n> parameter setting is stored in NVM and available at next reboot.
NOTE: 4G only products support <n> parameter value 28 only.
NOTE: 4G/3G only products support <n> parameter values 22, 28 and 31 only. 31
is factory default
NOTE: 4G/2G only products support <n> parameter values 12, 28 and 30 only. 30
Read command reports the currently selected cellular network, in the format:
Test command reports the range for the parameter <n>.
Facility Lock/Unlock - +CLCK
+CLCK - Facility Lock/Unlock
<fac>,<mode>
[,<passwd>
[,<class>]]
Execution command is used to lock or unlock a ME on a network facility.
Parameters:
<fac> - facility
"PS" - PH-SIM (lock Phone to SIM card) MT asks password when other than
current SIM card inserted; MT may remember certain amount of previously
used cards thus not requiring password when they are inserted
"PF" - lock Phone to the very First inserted SIM card (MT asks password when
other than the first SIM card is inserted)
"SC" - SIM (PIN request) (device asks SIM password at power-up and when this
lock command issued)
"AO"- BAOC (Barr All Outgoing Calls)
"OI" - BOIC (Barr Outgoing International Calls)
"OX" - BOIC-exHC (Barr Outgoing International Calls except to Home Country)
"AI" - BAIC (Barr All Incoming Calls)
"IR" - BIC-Roam (Barr Incoming Calls when Roaming outside the home country)