Save IP Port and IP Address for OTA over IP - #OTAIPCFG
#OTAIPCFG – Save IP port and IP address for OTA over IP
SELINT 2
AT#OTAIPCFG=<IPort>,<IP
addr>[,<unused>]
This command saves in NVM the IP port number and IP address of the
OTA server.
Parameters:
<IPort >: IP port of the OTA server
<IPaddr>: IP address of the OTA server, string type. This parameter can
be any valid IP address in the format: “xxx.xxx.xxx.xxx”
Note: the values set by the command are directly stored in NVM and don’t
depend on the specific CMUX instance.
Note2: a special form of the Set command, #OTAIPCFG=<IPort>,”” sets
the IP address to “0.0.0.0”.
AT#OTAIPCFG?
Read command reports the currently selected <IPort > and <IPaddr> in
the format:
#OTAIPCFG: <IPort >,<IPaddr>,0
AT#OTAIPCFG=?
Test command reports the range of supported values for parameters
<IPort> and <unused>