Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 320 of 509
Mod. 0808 2011-07 Rev.2
#CMGS - Send Message
SELINT 2
The entered text should be enclosed between double quotes and formatted as
follows:
- if current <dcs> (see +CSMP) indicates that GSM03.38 default alphabet is
used and current <fo> (see +CSMP) indicates that 3GPP TS 23.040 TP-
User-Data-Header-Indication is not set, then ME/TA converts the entered
text into GSM alphabet, according to 3GPP TS 27.005, Annex A.
- if current <dcs> (see +CSMP) indicates that 8-bit or UCS2 data coding
scheme is used or current <fo> (see +CSMP) indicates that 3GPP TS 23.040
TP-User-Data-Header-Indication is set, the entered text should consist of two
IRA character long hexadecimal numbers which ME/TA converts into 8-bit
octet (e.g. the ‘asterisk’ will be entered as 2A (IRA50 and IRA65) and this
will be converted to an octet with integer value 0x2A)
If message is successfully sent to the network, then the result is sent in the
format:
#CMGS: <mr>
where
<mr> - message reference number; 3GPP TS 23.040 TP-Message-Reference
in integer format.
Note: if message sending fails for some reason, an error code is reported.
AT#CMGS=?
Test command resturns the OK result code.
Note
To avoid malfunctions is suggested to wait for the #CMGS: <mr> or #CMS
ERROR: <err> response before issuing further commands.
Reference
3GPP TS 27.005
Write Message To Memory - #CMGW
#CMGW - Write Message To Memory
SELINT 2
(PDU Mode)
AT#CMGW=
<length>,<pdu>
(PDU Mode)
Execution command writes in the <memw> memory storage a new message.
Parameter:
<length> - length in bytes of the PDU to be written.
7..164
<pdu> - PDU in hexadecimal format (each octet of the PDU is given as two
IRA character long hexadecimal number) and given in one line.
If message is successfully written in the memory, then the result is sent in the
format:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions LE910 and is the answer not in the manual?

Telit Wireless Solutions LE910 Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelLE910
CategoryControl Unit
LanguageEnglish

Related product manuals