Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 252 of 509
Mod. 0808 2011-07 Rev.2
Note: for 4G/3G only product use fixed unused value 0 for <band> parameter.
Note: for 4G/2G only product use fixed unused value 0 for <UMTS band>
parameter.
Read command returns the current selected band in the format:
#BND: <band>,<UMTS band>,<LTE band>
Test command returns the supported range of values of parameters <band>,
<UMTS band> and <LTE band>.
Automatic Band Selection - #AUTOBND
#AUTOBND - Automatic Band Selection
[<value>]
Set command enables/disables the automatic band selection at power-on.
Parameter:
<value>:
0 - disables automatic band selection at next power-up
1 – value not supported.
2 – (default) enables automatic band selection in all supported bands; differently
from previous settings it takes immediate effect
Note: necessary condition to effectively have automatic band selection at next
power-up is that AT+COPS=0 has to be previously issued
Note: if the current setting is equal to AT#AUTOBND=0 and we’re issuing
AT#ENS=1, at first next power-up after the ENS functionality has been activated
(see #ENS) the automatic band selection (AT#AUTOBND=2) is enabled.
Read command returns whether the automatic band selection is enabled or not in
the form:
Test command returns the range of supported values for parameter <value>.