Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 235 of 509
Mod. 0808 2011-07 Rev.2
Extended Call Monitoring - #ECAM
#ECAM - Extended Call Monitoring
SELINT 2
AT#ECAM=
[<onoff>]
This command enables/disables the call monitoring function in the ME.
Parameter:
<onoff>
0 - disables call monitoring function (factory default)
1 - enables call monitoring function; the ME informs about call events, such as
incoming call, connected, hang up etc. using the following unsolicited
indication:
#ECAM: <ccid>,<ccstatus>,<calltype>,,,[<number>,<type>]
where
<ccid> - call ID
<ccstatus> - call status
0 - idle
1 - calling (MO)
2 - connecting (MO)
3 - active
4 - hold
5 - waiting (MT)
6 - alerting (MT)
7 - busy
<calltype> - call type
1 - voice
2 - data
<number> - called number (valid only for <ccstatus>=1)
<type> - type of <number>
129 - national number
145 - international number
Note: the unsolicited indication is sent along with usual codes (OK, NO
CARRIER, BUSY...).
AT#ECAM?
Read command reports whether the extended call monitoring function is
currently enabled or not, in the format:
#ECAM: <onoff>
AT#ECAM=?
Test command returns the list of supported values for <onoff>