EasyManua.ls Logo

Telit Wireless Solutions LE910 - Page 318

Telit Wireless Solutions LE910
509 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 318 of 509
Mod. 0808 2011-07 Rev.2
#EVMONI Set the single Event Monitoring
SELINT 2
o if <paramType> = 2, <param> indicates the status high or low
under monitoring. The values are 0 (low) and 1 (high) . (Default: 0)
o if <paramType> = 3, <param>
indicates the time interval in
seconds after that the selected GP
IO pin in the status specified with
<paramType> = 1 causes the event. The range is 0 255. (Default:
0)
If <label> is ADCH1, <paramType> can assume values in the range 0 - 3.
o if <paramType> = 1, <param>
indicates the ADC pin number;
supported range is from 1 to a value that depends on the hardware.
(Default: 1)
o if <paramType> = 2, <param>
indicates the ADC High voltage
threshold in the range 0 – 2000 mV. (Default: 0)
o if <paramType> = 3, <param>
indicates the time interval in
seconds after that the selected
ADC pin above the value specified
with <paramType> = 1 causes the event. The range is 0 255.
(Default: 0)
If <label> is ADCL1, <paramType> can assume values in the range 0 - 3.
o if <paramType> = 1, <param>
indicates the ADC pin number;
supported range is from 1 to a value that depends on the hardware.
(Default: 1)
o if <paramType> = 2, <param>
indicates the ADC Low voltage
threshold in the range 0 – 2000 mV. (Default: 0)
o if <paramType> = 3, <param>
indicates the time interval in
seconds after that the selec
ted ADC pin under the value specified
with <paramType> = 1 causes the event. The range is 0 255.
(Default: 0)
If <label> is DTMFX, <paramType> can assume values in the range 0 - 2.
o if <paramType> = 1, <param>
indicates the DTMF string; the
single DTMF characters have to belong to the range ((0-9),#,*,(A-
D)); the maximum number of characters in the string is 15
o if <paramType> = 2, <param>
indicates the timeout in
milliseconds. It is the maximum time interval within which a DTMF
tone must be detected after detecting the previous one, to be
considered as belonging to the DTMF string. The range is (500
5000). (Default: 1000)
If <label> is SMSIN, <paramType> can assume values in the range 0-1.
o if <paramType> = 1, <param>
indicates the text that must be
received in incoming SMS to trigger AT command execution rings
after that the event occurs; the maximum number of characters in the
SMS text string is 15
. If no text is specified, AT command execution
is triggered after each incoming SMS
If <label> is CONSUMEX, <paramType> can assume only the value 0.
Note: the DTMF string monitoring is available only if the DTMF decode has been
enabled (see #DTMF command)

Table of Contents

Related product manuals