Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 290 of 509
Mod. 0808 2011-07 Rev.2
#CSURVC - Network Survey (Numeric Format)
SELINT 2
<ecio> - decimal number; it is the EC/IO ratio level (in dB)
(For non BCCH-Carrier)
<uarfcn>,<rxLev>
where:
<uarfcn>
- decimal number; it is the RF channel
<rxLev>
- decimal number; it is the receiption level (in dBm)
The last information from
#CSURVC
depends on the last
#CSURVF
setting:
#CSURVF=0
or
#CSURVF=1
The output ends with the string:
Network survey ended
#CSURVF=2
the output ends with the string:
Network survey ended (Carrier: <NoARFCN> BCCh: <NoBCCh>)
where
<NoARFCN
> - number of scanned frequencies
<NoBCCH> - number of found BCCh
Example
AT#CSURVC
Network survey started…
36,49,-80,0.00,222,10,20060,27162,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0
10588,-92,222,88,54,19406101,24065,0-100,-8.0
Network survey ended
OK
Notes
and
Platform limits
This command execution takes a long time especially if the full band scan is
performed.
The information provided by
#CSURVC
is the same as that provided by
#CSURV
. The difference is that the output of
#CSURVC
is in numeric
format only.
The module must be configured in +COPS: 2 mode.
The limits described for
#CSURV
are also valid for
#CSURVC
.

Table of Contents