Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 303 of 509
Mod. 0808 2011-07 Rev.2
#TCPATCONSER – Connects the TCP Run AT service to a serial port
6 – SPI
Not all of these ports will be available at the same time.
The ports available will be displayed by the test command. They depend on
the AT#PORTCFG command.
Please refer to that AT command and to the “HE Family Ports
Arrangements User Guide” for a detailed explanation of all port
configurations
< rate >
baud rate for data transfer. Allowed values are
300,1200,2400,4800,9600,19200,38400,57600,115200.
Note1: the command has to be issued from the TCP ATRUN instance
Note2: After this command has been issued, if no error has occurred, then a
“CONNECT” will be returned by the module to advise that the TCP
ATRUN instance is in online mode and connected to the port specified.
Note3: To exit from online mode and close the connection, the escape
sequence (+++) has to be sent on the TCP ATRUN instance
Note4: for USB ports and SPI the rate parameter is dummy
Test command returns the supported values for the TCPATCONSER
parameters