Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 477 of 509
Mod. 0808 2011-07 Rev.2
#OTASUAN – OTA Set User Answer
SELINT 2
#OTAEV: Fw Download Complete
The firmware download is finished
#OTAEV: OTA Fw Upgrade Failed
The Fw upgrade has failed
#OTAEV: Module Upgraded To New Fw
The Fw upgrade is successfully finished
#OTAEV: Server notified about successful FW Upgrade
The final SMS has been sent to the server notifying the successful FW upgrade
"#OTAEV: Registered"
The module has registered itself to a server
"#OTAEV: Not registered"
The registration procedure has failed
"#OTAEV: Company Name Registered"
The company name is registered
"#OTAEV: Company Name not registered"
The company name is not registered
"#OTAEV: Provisioned"
A server has provisioned the module
"#OTAEV: Notified"
A server has notified the module
AT# OTASUAN?
Read command reports the current settings in the format:
#OTASUAN: ,<mode>,<bfr>
AT#OTASUAN =?
Test command returns values supported as a compound value
Example
AT#OTASUAN=,2,1
OK
AT#OTASUAN?
#OTASUAN: ,2,1
OK
AT#OTASUAN =?
#OTASUAN: (0-2),(0-2),(0,1)
OK