Telit LE910 V2 Series AT Commands
80446ST10707A Rev. 0– 2015-11-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 63 of 509
Mod. 0808 2011-07 Rev.2
+CESQ – Extended Signal Quality
2-19 dB ≤ rsrq < -18.5 dB
...
32 - -4 dB ≤ rsrq < -3.5 dB
33 - -3.5 dB ≤ rsrq < -3 dB
34 - -3 dB ≤ rsrq
255 - not known or not detectable detectable or if the current serving cell is not a
EUTRA cell
<rsrp> - type, reference signal received power (see 3GPP TS 36.133 subclause
9.1.4).
0 - rsrp < -140 dBm
1 - -140 dBm ≤ rsrp < -139 dBm
2 - -139 dBm ≤ rsrp < -138 dBm
...
95 - -46 dBm ≤ rsrp < -45 dBm
96 - -45 dBm ≤ rsrp < -44 dBm
97 - -44 dBm ≤ rsrp
255 not known or not detectable detectable or if the current serving cell is not
Test command returns the supported range of values of the parameters <rxlev>,
<ber>, <rscp>, <ecno>, <rsrq>, <rsrp>.