rep block port
To configure a REP VLAN load balancing on the REP primary edge port, use the rep block port command
in interface configuration mode. To return to the default configuration with VLAN 1 as the administrative
VLAN, use the no form of this command.
rep block port {id port-id | neighbor-offset | preferred} vlan {vlan-list | all}
no rep block port {id port-id | neighbor-offset | preferred}
Syntax Description
Specifies the VLAN blocking alternate port by entering the unique port ID, which is
automatically generated when REP is enabled. The REP port ID is a 16-character
hexadecimal value. You can display the port ID for an interface by entering the show
interface interface-id rep detail command in privileged EXEC mode.
id port-id
Identifies the VLAN blocking alternate port by entering the offset number of a
neighbor. The range is from -256 to +256; a value of 0 is invalid.
neighbor-offset
Selects the regular segment port previously identified as the preferred alternate port
for VLAN load balancing.
preferred
Identifies the VLANs to be blocked.vlan
VLAN ID or range of VLAN IDs to be displayed. Enter a VLAN ID from 1 to 4094
or a range or sequence of VLANs (such as 1-3, 22, 41-44) to be blocked.
vlan-list
Blocks all the VLANs.all
Command Default
The default behavior after you enter the rep preempt segment command in privileged EXEC (for manual
preemption) is to block all VLANs at the primary edge port. This behavior remains until you configure the
rep block port command.
If the primary edge port cannot determine which port is to be the alternate port, the default action is no
preemption and no VLAN load balancing.
Command Modes
Interface configuration (config-if)
Command History
ModificationRelease
This command was introducedCisco IOS XE Denali 16.2.2
Usage Guidelines
You must enter this command on the REP primary edge port.
Command Reference, Cisco IOS XE Everest 16.5.1a (Catalyst 3650 Switches)
327
rep block port

Table of Contents

Other manuals for Cisco Catalyst 3650 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3650 Series and is the answer not in the manual?

Cisco Catalyst 3650 Series Specifications

General IconGeneral
RAM4 GB
Flash Memory4 GB
Ports24 or 48 10/100/1000 Ethernet ports
Uplinks4 x 1G SFP or 4 x 10G SFP+ (depending on model)
StackingUp to 9 switches with StackWise-160
Layer SupportLayer 2, Layer 3
SoftwareCisco IOS Software
Power SupplyInternal power supply; optional redundant power supply available
Storage Temperature-40°F to 158°F (-40°C to 70°C)

Related product manuals