EasyManua.ls Logo

Cisco Catalyst 3650 Series - Test Mcu Read-Register

Cisco Catalyst 3650 Series
1108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
test mcu read-register
To enable debugging of the Power over Ethernet (PoE) controller, use the test mcu read-register command
in privileged EXEC mode.
test mcu read-register {det-cls-offset| manufacture-id| port-mode}
Syntax Description
Displays the read detection classification register summary.det-cls-offset
Displays the PoE controller manufacture ID.manufacture-id
Displays the port mode details.port-mode
Command Modes
Privileged EXEC
Command History
ModificationRelease
This command was introduced.Cisco IOS XE 3.3SE
Examples
The following is sample output from the test mcu read-register det-cls-offset command:
Device# test mcu read-register det-cls-offset 1
DETECTION ENABLE BIT SUMMARY
Controller port1 port2 port3 port4 register
(hexadecimal)
---------- ------- ------- ------- ------- ------------
1 1 0 1 0 5
2 1 0 1 0 5
3 1 0 1 0 5
4 1 0 1 0 5
5 1 0 1 0 5
6 1 0 1 0 5
7 1 0 1 0 5
8 1 0 1 0 5
9 1 0 1 0 5
10 1 0 1 0 5
11 0 0 1 0 4
12 1 0 0 0 1
CLASSIFICATION ENABLE BIT SUMMARY
Command Reference, Cisco IOS XE Everest 16.5.1a (Catalyst 3650 Switches)
132
test mcu read-register

Table of Contents

Other manuals for Cisco Catalyst 3650 Series

Related product manuals