EasyManuals Logo

Cisco Catalyst 3650 Series User Manual

Cisco Catalyst 3650 Series
1108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #712 background imageLoading...
Page #712 background image
IPv6 CEF is disabled globally or locally on an interface
The bfd interval configuration is removed when the subinterface on which its is configured is removed.
If we configure bfd interval command in interface config mode, then bfd echo mode is enabled by default.
We need to enable either no ip redirect (if BFD echo is needed) or no bfd echo in interface config mode.
Before using BFD echo mode, you must disable sending Internet Control Message Protocol (ICMP)
redirect messages by entering the no ip redirect command, in order to avoid high CPU utilization.
Note
Examples
The following example shows the BFD session parameters set for Gigabit Ethernet 1/0/3:
Device> enable
Device# configuration terminal
Device(config)# interface gigabitethernet 1/0/3
Device(config-if)# bfd interval 100 min_rx 100 multiplier 3
Command Reference, Cisco IOS XE Everest 16.5.1a (Catalyst 3650 Switches)
686
bfd

Table of Contents

Other manuals for Cisco Catalyst 3650 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3650 Series and is the answer not in the manual?

Cisco Catalyst 3650 Series Specifications

General IconGeneral
RAM4 GB
Flash Memory4 GB
Ports24 or 48 10/100/1000 Ethernet ports
Uplinks4 x 1G SFP or 4 x 10G SFP+ (depending on model)
StackingUp to 9 switches with StackWise-160
Layer SupportLayer 2, Layer 3
SoftwareCisco IOS Software
Power SupplyInternal power supply; optional redundant power supply available
Storage Temperature-40°F to 158°F (-40°C to 70°C)

Related product manuals