mode random 1 out-of
To enable random sampling and to specify the packet interval for a Flexible NetFlow sampler, use the mode
random 1 out-of command in sampler configuration mode. To remove the packet interval information for a
Flexible NetFlow sampler, use the no form of this command.
mode random 1 out-of window-size
no mode
Syntax Description
Specifies the window size from which to select packets. The range is 2 to
1024.
window-size
Command Default
The mode and the packet interval for a sampler are not configured.
Command Modes
Sampler configuration
Command History
ModificationRelease
This command was introduced.Cisco IOS XE 3.3SE
Usage Guidelines
A total of four unique samplers are supported on the . Packets are chosen in a manner that should eliminate
any bias from traffic patterns and counter any attempt by users to avoid monitoring.
The deterministic keyword is not supported, even though it is visible in the command-line help string.Note
Examples
The following example enables random sampling with a window size of 1000:
Device(config)# sampler SAMPLER-1
Device(config-sampler)# mode random 1 out-of 1000
Command Reference, Cisco IOS XE Everest 16.5.1a (Catalyst 3650 Switches)
457
mode random 1 out-of

Table of Contents

Other manuals for Cisco Catalyst 3650 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3650 Series and is the answer not in the manual?

Cisco Catalyst 3650 Series Specifications

General IconGeneral
RAM4 GB
Flash Memory4 GB
Ports24 or 48 10/100/1000 Ethernet ports
Uplinks4 x 1G SFP or 4 x 10G SFP+ (depending on model)
StackingUp to 9 switches with StackWise-160
Layer SupportLayer 2, Layer 3
SoftwareCisco IOS Software
Power SupplyInternal power supply; optional redundant power supply available
Storage Temperature-40°F to 158°F (-40°C to 70°C)