Page #482 background imageLoading...
Page #482 background image
match transport icmp ipv6
To configure the ICMP IPv6 type field and the code field as key fields for a flow record, use the match
transport icmp ipv6 command in flow record configuration mode. To disable the use of the ICMP IPv6 type
field and code field as key fields for a flow record, use the no form of this command.
match transport icmp ipv6 {code| type}
no match transport icmp ipv6 {code| type}
Syntax Description
Configures the IPv6 ICMP code as a key field.
code
Configures the IPv6 ICMP type as a key field.
type
Command Default
The ICMP IPv6 type field and the code field are not configured as key fields.
Command Modes
Flow record configuration
Command History
ModificationRelease
This command was introduced.Cisco IOS XE 3.3SE
Usage Guidelines
A flow record requires at least one key field before it can be used in a flow monitor. The key fields distinguish
flows, with each flow having a unique set of values for the key fields. The key fields are defined using the
match command.
Examples
The following example configures the IPv6 ICMP code field as a key field:
Device(config)# flow record FLOW-RECORD-1
Device(config-flow-record)# match transport icmp ipv6 code
The following example configures the IPv6 ICMP type field as a key field:
Device(config)# flow record FLOW-RECORD-1
Device(config-flow-record)# match transport icmp ipv6 type
Command Reference, Cisco IOS XE Everest 16.5.1a (Catalyst 3650 Switches)
456
match transport icmp ipv6

Table of Contents

Other manuals for Cisco Catalyst 3650 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3650 Series and is the answer not in the manual?

Cisco Catalyst 3650 Series Specifications

General IconGeneral
RAM4 GB
Flash Memory4 GB
Ports24 or 48 10/100/1000 Ethernet ports
Uplinks4 x 1G SFP or 4 x 10G SFP+ (depending on model)
StackingUp to 9 switches with StackWise-160
Layer SupportLayer 2, Layer 3
SoftwareCisco IOS Software
Power SupplyInternal power supply; optional redundant power supply available
Storage Temperature-40°F to 158°F (-40°C to 70°C)