Examples
This example shows how to display information about stack member 1 from the master switch:
Device> show env stack 1
Device 1:
Device Fan 1 is OK
Device Fan 2 is OK
Device Fan 3 is OK
FAN-PS1 is OK
FAN-PS2 is NOT PRESENT
Device 1: SYSTEM TEMPERATURE is OK
Temperature Value: 32 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 41 Degree Celsius
Red Threshold : 56 Degree Celsius
Device>
This example shows how to display temperature value, state, and threshold values:
Device> show env temperature status
Temperature Value: 32 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 41 Degree Celsius
Red Threshold : 56 Degree Celsius
Device>
Table 49: States in the show env temperature status Command Output
DescriptionState
The switch temperature is in the normal operating
range.
Green
The temperature is in the warning range. You should
check the external temperature around the switch.
Yellow
The temperature is in the critical range. The switch
might not run properly if the temperature is in this
range.
Red
Command Reference, Cisco IOS XE Everest 16.5.1a (Catalyst 3650 Switches)
949
show env