EasyManuals Logo

Kollmorgen AKD Basic User Manual

Kollmorgen AKD Basic
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #247 background imageLoading...
Page #247 background image
AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.11.30 DRV.SETUPREQBITS
General Information
Type R/O Parameter
Description
Reads the bitwise set status of parameters that must be set before the drive
can be enabled
Units N/A
Range N/A
Default
Value
N/A
Data Type N/A
See Also DRV.SETUPREQLIST, MOTOR.AUTOSET
Start Ver-
sion
M_01-00-00-000
Description
This parameter returns the bitwise set status of parameters that needs to be set up before the
drive can be enabled. Only when this parameter returns 0 can the drive be enabled.
Parameter Bits
IL.KP 0x00000001
MOTOR.IPEAK 0x00000002
MOTOR.ICONT 0x00000004
MOTOR.VMAX 0x00000008
MOTOR.POLES 0x00000010
MOTOR.PHASE 0x00000020
Please note that if MOTOR.AUTOSET is set to 1 (parameters automatically calculated from
motor IDdata), then all values in the list will be initialized from the feedback device. Otherwise,
the parameters must be set manually.
247 Kollmorgenâ„¢ | March 30, 2012