AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.12.7 EGEAR.PULSEOUT
General Information
Type R/W
Description
Specifies the number of position counts used in an exact electronic gearing
ratio.
Units Position counts
Range -CountsPerRev/2 to CountsPerRev/2
Default
Value
1
Data Type Integer
Start Ver-
sion
TBD
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 1072 No 8 bit Yes M_01-05-11-000
Description
EGEAR.PULSESOUT is the number of position counts the motor moves for each EGEAR.PU-
LSESIN number of encoder counts. EGEAR.PULSESOUT must be set more recently than
EGEAR.RATIO in order to use exact electronic gearing.
Related Topics
EGEAR.PULSESIN | EGEAR.RATIO |EGEAR.ON | FB2.SOURCE | FB2.ENCRES |
FB2.MODE
259 Kollmorgen | March 30, 2012