EasyManuals Logo

Kollmorgen AKD Basic User Manual

Kollmorgen AKD Basic
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #436 background imageLoading...
Page #436 background image
AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.31.6 UNIT.POUT
General Information
Type NV Parameter
Description
Sets gear out for the unit con-
version.
Units User units.
Range 0 to 4,294,967,295
Default
Value
20
Data Type Integer
See Also UNIT.PLINEAR
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
35CBh/0
6092h/2
M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 784 No 32 bit No M_01-03-00-000
Description
UNIT.POUT is used in conjunction with UNIT.PLINEAR to set application specific units in
UNIT.POUT. This parameter is used as follows in the drive unit conversion:
l For position, this parameter sets the units as [custom units]/rev.
l For velocity, this parameter sets the units as [custom units]/s.
l For acceleration/deceleration, this parameter sets the units as [custom units]/s
2
.
Kollmorgenâ„¢ | March 30, 2012 436

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD Basic and is the answer not in the manual?

Kollmorgen AKD Basic Specifications

General IconGeneral
BrandKollmorgen
ModelAKD Basic
CategoryController
LanguageEnglish

Related product manuals