EasyManua.ls Logo

Kollmorgen AKD Basic

Kollmorgen AKD Basic
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.25.1 PL.CMD
General Information
Type R/O Parameter
Description
Reads the position command directly from the entry to the position
loop.
Units
Depends on UNIT.PROTARY or UNIT.PLINEAR UNIT.ACCLINEAR
Rotary: counts, rad, deg, (custom units), 16-bit counts
Linear: counts, mm, µm, (custom units), 16-bit counts
Range N/A
Default
Value
N/A
Data Type Float
See Also PL.FB
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 570 Yes 64 bit No M_01-03-00-000
AKD BASIC Information
Data Type Integer
Description
PL.CMD reads the position command as it is received in the position loop entry.
Related Topics
PL.ERR | PL.ERRFTHRESH | PL.ERRMODE | PL.ERRWTHRESH
Kollmorgen | March 30, 2012 382

Table of Contents