EasyManuals Logo

Kollmorgen AKD Basic User Manual

Kollmorgen AKD Basic
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #134 background imageLoading...
Page #134 background image
AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.3.8 AIN.VALUE
General Information
Type R/O Parameter
Description
Reads the value of the analog input sig-
nal.
Units V
Range -12.5 to +12.5 V
Default
Value
N/A
Data Type Float
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
3470h/4
3509h/0
M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 12 No 16 bit No M_01-03-00-000
Description
AIN.VALUE reads the analog input value after the value is filtered (as shown in the Analog
Input Block Diagram).
Kollmorgenâ„¢ | March 30, 2012 134

Table of Contents