AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.23.19 MOTOR.TEMPWARN
General Information
Type NV Parameter
Description
Sets the motor temperature warning
level.
Units Ω
Range 0 to 2,000,000,000 Ω
Default
Value
0 Ω = switched off
Data Type Integer
See Also MOTOR.TEMP
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
3453h/0 M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 518 No 32 bit No M_01-03-00-000
Description
This parameter is used to configure the motor temperature warning level as a resistance thresh-
old of the motor PTC.
A zero value prevents any warning from being created.
357 Kollmorgenâ„¢ | March 30, 2012