EasyManuals Logo

Kollmorgen AKD Basic User Manual

Kollmorgen AKD Basic
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #414 background imageLoading...
Page #414 background image
AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.27.2 REC.DONE
General Information
Type R/O Parameter
Description
Checks whether or not the recorder has finished record-
ing.
Units N/A
Range 0 to 1
Default
Value
N/A
Data Type Integer
See Also REC.ACTIVE, REC.OFF
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 710 No 8 bit No M_01-03-00-000
Description
REC.DONE indicates that the recorder has finished recording. This value is reset to 0 when the
recorder trigger is set. The drive also resets this value when the recording has finished or when
REC.OFF is executed.
Kollmorgenâ„¢ | March 30, 2012 414