AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.32.1 VBUS.OVFTHRESH
General Information
Type R/O Parameter
Description
Reads the over voltage fault
level.
Units Vdc
Range 0 to 900 Vdc
Default
Value
N/A
Data Type Integer
See Also VBUS.UVFTHRESH
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 794 No 16 bit No M_01-03-00-000
Description
VBUS.OVFTHRESH reads the over voltage fault level for the DC bus.
This value is read from the drive EEPROM and varies according to the drive type.