AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.10.6 DOUT1.STATEU AND DOUT2.STATEU
General Information
Type R/W Parameter
Description
Sets the state of the digital output
node.
Units N/A
Range 0 to 1
Default
Value
0
Data Type Integer
See Also N/A
Start Version M_01-01-01-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus
204 DOUT1.STATEU
No 8 bit No M_01-03-00-000
214 DOUT2.STATEU
Description
DOUT1.STATEU and DOUT2.STATEU set the state of the digital output node as follows:
0 = deactivated
1 = activated
DOUT1.STATEU and DOUT2.STATEUare used when DOUT8.MODE to DOUT11.MODE =
0 (user mode).