EasyManuals Logo

Kollmorgen AKD Basic User Manual

Kollmorgen AKD Basic
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #426 background imageLoading...
Page #426 background image
AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.30.1 SWLS.EN
General Information
Type NV Parameter
Description
Enables and disables software travel limit
switches.
Units N/A
Range 0 to 3
Default
Value
0
Data Type U8
See Also DRV.MOTIONSTAT
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 764 No 16 bit No M_01-03-00-000
Description
This parameter enables the software travel limit switches. The software limit switches are only
active if the axis is homed.
Example
Bit 0 = 0: Disable SWLS.LIMIT0
Bit 0 = 1: Enable SWLS.LIMIT0
Bit 1 = 0: Disable SWLS.LIMIT1
Bit 1 = 1: Enable SWLS.LIMIT1
Related Topics
1 Limits
1 Homing
HOME Parameters
Kollmorgenâ„¢ | March 30, 2012 426

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD Basic and is the answer not in the manual?

Kollmorgen AKD Basic Specifications

General IconGeneral
BrandKollmorgen
ModelAKD Basic
CategoryController
LanguageEnglish

Related product manuals