AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.34.1 VM.AUTOSTART
General Information
Type R/W
Description
VM.AUTOSTART specifies whether or not the
program in the AKD BASIC starts executing auto-
matically when AC power is applied.
Units none
Range 0 to 1
Default
Value
0
Data Type Integer
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 1152 No 32 bit No M_01-05-11-000
Description
VM.AUTOSTART specifies whether or not the program in the AKD BASIC starts executing
automatically when AC power is applied.
l 0 = Program does not start automatically
l 1 = Program starts automatically
Set VM.AUTOSTART to 0 or 1 in the terminal in WorkBench and execute an NVSave.