AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.19.4 IL.DFOLDT
General Information
Type R/W Parameter
Description
Reads the drive foldback time constant of the exponential current drop (fold-
back).
Units s
Range 1 to 65.535 s
Default
Value
Usually 2.500 s, but may change according to the drive type.
Data Type Float
Start Ver-
sion
M_01-00-00-000
Description
IL.DFOLDT is the time constant of the exponential drop (foldback) of the current towards the
drive continuous current.
Kollmorgenâ„¢ | March 30, 2012 308