AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.19.17 IL.MFOLDD
General Information
Type R/O Parameter
Description
Sets the motor foldback maximum time at motor peak cur-
rent.
Units s
Range 0.1 to 2400 s
Default
Value
10 s
Data Type Float
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 464 No 32 bit No M_01-03-00-000
Description
IL.MFOLDD sets the maximum time allowed for the motor to remain at peak current before
starting to fold towards the motor continuous current. When at motor peak current, IL.MFOLDD
is the amount of time before the foldback algorithm starts to reduce the current.