AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.28.1 REGEN.POWER
General Information
Type R/O parameter
Description
Reads regen resistor's calculated
power.
Units Watt
Range N/A
Default
Value
N/A
Data Type Integer
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
3416h/0
M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 734 Yes 64 bit No M_01-03-00-000
Description
This parameter reads regen resistor's calculated power, which is determined as follows:
(V
2
/ R) * DutyCycle
Kollmorgenâ„¢ | March 30, 2012 418