AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.26.4 PLS.RESET
General Information
Type R/O Parameter
Description Resets programmable limit switch.
Units N/A
Range 0 to 255
Default
Value
N/A
Data Type Integer
See Also
PLS.EN, PLS.MODE, PLS.STATE, PLS.UNITS, PLS.Px (x=1…8),
PLS.WIDTHx (x=1…8), PLS.Tx (x=1…8)
Start Ver-
sion
M_01-02-03-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
34A3h/2 M_01-02-03-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 654 No 16 bit No M_01-03-00-000
Description
This parameter is a bit variable and is used in order to re-arm the corresponding PLS.STATE
observation for another single-shot PLS use (see also PLS.MODE).
Example
Bit Value Behavior
Bit 0 = 0
The PLS 1 observation (PLS.STATE bit 0) is not re-
armed.
Bit 0 = 1 The PLS 1 observation (PLS.STATE bit 0) is re-armed.
Bit 7 = 0
The PLS 8 observation (PLS.STATE bit 7) is not re-
armed.
Bit 7 = 1 The PLS 8 observation (PLS.STATE bit 7) is re-armed.