AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.32.6 VBUS.UVWTHRESH
General Information
Type NV Parameter
Description Sets voltage level for undervoltage warning.
Units Vdc
Range 0 to 900 Vdc
Default
Value
10 volts above the default value of the under voltage fault threshold
(VBUS.UVFTHRESH). The default value of VBUS.UVFTHRESH is hardware
dependent.
Data Type U16
See Also VBUS.UVFTHRESH
Start Ver-
sion
M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 804 No 16 bit No M_01-03-00-000
Description
If VBUS.VALUE value drops below VBUS.UVWTHRESH, then a warning is generated.