EasyManua.ls Logo

Kollmorgen AKD Basic

Kollmorgen AKD Basic
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.11.11 DRV.DISSOURCES
General Information
Type R/O Parameter
Description Returns the possible reason for a drive disable.
Units N/A
Range N/A
Default
Value
N/A
Data Type Integer
See Also
DRV.ACTIVE, DRV.FAULTS, DRV.EN,
DRV.DIS
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 240 No 16 bit No M_01-03-00-000
Description
DRV.DISSOURCES is a bitwise parameter that returns the status of possible causes of a
drive disable. If this parameter is 0, then the drive is enabled.
The return value specific bits are as follows:
Bit Status and Response
0 Software disable (execute DRV.EN to issue software enable)
1 Fault exists (read DRV.FAULTS to get the active faults)
2 Hardware disable (remote enable input is low)
3 In-rush disable (the in-rush relay is opened)
4
Initialization disable (the drive did not finish the initialization proc-
ess)
5 Controlled stop disable from a digital input.
Related Topics
1 Controlled Stop
227 Kollmorgen | March 30, 2012

Table of Contents

Related product manuals