AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.11.11 DRV.DISSOURCES
General Information
Type R/O Parameter
Description Returns the possible reason for a drive disable.
Units N/A
Range N/A
Default
Value
N/A
Data Type Integer
See Also
DRV.ACTIVE, DRV.FAULTS, DRV.EN,
DRV.DIS
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 240 No 16 bit No M_01-03-00-000
Description
DRV.DISSOURCES is a bitwise parameter that returns the status of possible causes of a
drive disable. If this parameter is 0, then the drive is enabled.
The return value specific bits are as follows:
Bit Status and Response
0 Software disable (execute DRV.EN to issue software enable)
1 Fault exists (read DRV.FAULTS to get the active faults)
2 Hardware disable (remote enable input is low)
3 In-rush disable (the in-rush relay is opened)
4
Initialization disable (the drive did not finish the initialization proc-
ess)
5 Controlled stop disable from a digital input.
Related Topics
1 Controlled Stop
227 Kollmorgenâ„¢ | March 30, 2012

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD Basic and is the answer not in the manual?

Kollmorgen AKD Basic Specifications

General IconGeneral
BrandKollmorgen
ModelAKD Basic
CategoryController
LanguageEnglish

Related product manuals