6.5.5 CAM.MASTER
General Information
Type R/W
Description Specifies the source of the input to the cam table for cam profiling.
Units None
Range 0 to 2
Default
Value
0
Data Type Integer
Start Version M_01-06-00-000
Description
CAM.MASTER takes one of the following values:
Value Description
0 EXTENCODER.POSITION + CAMVM.POSITION
1 CAMVM.POSITION only (EXTENCODER.POSITION is ignored)
2 EXTENCODER.POSITION only (CAMVM.POSITION is ignored)