AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.33.12 VL.FBSOURCE
General Information
Type NV Parameter
Description
Sets feedback source for the velocity loop; active in opmodes 1 (velocity) and 2
(position) only.
Units N/A
Range 0 to 1
Default
Value
0
Data Type Integer
See Also PL.FBSOURCE
Start Ver-
sion
M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 860 No 8 bit No M_01-03-00-000
Description
This parameter determines the feedback source to be used by the velocity loop. A value of 0
selects the primary feedback, 1 selects the secondary feedback.
Kollmorgenâ„¢ | March 30, 2012 464