6.19.11 IL.IUFB
General Information
Type R/O Parameter
Description
Reads the sigma-delta measured current in the u-winding of the
motor.
Units A
Range ± Drive peak current (DRV.IPEAK)
Default
Value
N/A
Data Type Float
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 446 No 32 bit Yes M_01-03-00-000
Description
This parameter displays the measured current in the u-winding of the motor.