AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.6.10 CAP0.STATE, CAP1.STATE
General Information
Type R/O Parameter
Description
Indicates whether or not trigger source was cap-
tured.
Units N/A
Range 0 to 1
Default
Value
0
Data Type Integer
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed?
Object
Start
Version
Modbus
74 CAP0.STATE
No 8 bit No
M_01-
03-00-
000
100 CAP1.STATE
Description
When enabling the capture (CAP0.EN, CAP1.EN ), this parameter is set to 0 until the next
event is captured.
0 = Not captured orCapture Disabled
1 = Captured