AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.23.18 MOTOR.TEMPFAULT
General Information
Type NV Parameter
Description
Sets the motor temperature fault
level.
Units
Range 0 to 2,000,000,000
Default
Value
0 = switched off
Data Type Integer
See Also MOTOR.TEMP
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
3586h/0 M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 516 No 32 bit No M_01-03-00-000
Description
This parameter is used to configure the motor temperature fault level as a resistance threshold
of the motor PTC.
A zero value prevents any warning from being issued.