AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.28.2 REGEN.REXT
General Information
Type NV Parameter
Description
Sets the external, user-defined regen resistor resist-
ance.
Units Ω
Range 0 to 255 Ω
Default
Value
0 Ω
Data Type Integer
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
35C2h/0 M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 738 No 16 bit No M_01-03-00-000
Description
REGEN.REXT sets the external user-defined regen resistor resistance. This variable is
needed for the regen resistor temperature estimation algorithm.
419 Kollmorgenâ„¢ | March 30, 2012