EasyManuals Logo

Kollmorgen AKD Basic User Manual

Kollmorgen AKD Basic
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #442 background imageLoading...
Page #442 background image
AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.32.2 VBUS.OVWTHRESH
General Information
Type NV Parameter
Description
Sets voltage level for over voltage warn-
ing.
Units Vdc
Range 0 to 900 Vdc
Default
Value
0 Vdc (warning disabled)
Data Type U16
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 796 No 16 bit No M_01-03-00-000
Description
If VBUS.VALUE value exceeds VBUS.OVWTHRESH, then a warning is generated.