AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.5.10 CAMVM.GOREL
General Information
Type Statement
Description
Makes the virtual master move the distance specified by CAMVM.RE-
LATIVEDIST.
Units None
Range N/A
Default
Value
N/A
Data Type N/A
Start Ver-
sion
M_01-06-00-000
Description
CAMVM.GOREL (Go Relative) causes the virtual master to move a distance specified by
CAMVM.RELATIVEDIST. The virtual master runs at the frequency specified by
CAMVM.FREQ. Use CAMVM.GOUPDATE to modify this frequency during the move.
Program execution continues with the line immediately following the CAMVM.GOREL state-
ment as soon as the move is initiated. Program execution does not wait until the move is com-
plete. The drive does not need to be enabled in order for to use the virtual master.
Related Topics
CAMVM.GOVEL | CAMVM.STOP | CAMVM.GOUPDATE
165 Kollmorgenâ„¢ | March 30, 2012