AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.10.2 DOUT.STATES
General Information
Type R/O Parameter
Description
Reads the state of the two digital out-
puts.
Units N/A
Range 0 to 11
Default
Value
N/A
Data Type String
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 194 No 8 bit No M_01-03-00-000
AKD BASIC Information
Data Type Integer
Description
DOUT.STATES reads the states of the two digital outputs. The rightmost bit represents
DOUT2 and the leftmost bit represents DOUT1.