AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.11.22 DRV.HWENABLE
General Information
Type R/O
Description Status of the hardware enable .
Units N/A
Range 0 to 1
Default
Value
N/A
Data Type Integer
Start Version tbd
Fieldbus Index/Subindex Is 64 bit? Attributes Signed?
Modbus 1054 No 8 bit No
Description
Status of the Hardware Enable.
0 - not enabled
1 - enabled
Notes: This parameter reflects the status of the hardware enable only, not if the status of the
power stage. The status of the power stage enable is determined by DRV.ACITVE.
Related Topics
DRV.DISSOURCES | DRV.ACTIVE