AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.32.3 VBUS.RMSLIMIT
General Information
Type R/O Parameter
Description
Reads the limit for the bus capacitors
load.
Units Vrms
Range N/A
Default
Value
N/A
Data Type Integer
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 798 No 8 bit No M_01-03-00-000
Description
This parameter reads the limit of the bus capacitor load. When the bus capacitor loads exceeds
this limit, the drive generates fault F503.
Excessive bus capacitor load may indicate a disconnected main supply phase.
443 Kollmorgenâ„¢ | March 30, 2012