AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.3.6 AIN.OFFSET
General Information
Type NV Parameter
Description
Sets the analog input off-
set.
Units V
Range –10 to +10 V
Default
Value
0 V
Data Type Float
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 6 No 16 bit Yes M_01-03-00-000
Description
AIN.OFFSET sets the analog offset, which is added to the analog input command to the drive.
This value compensates for the analog input signal (AIN.VALUE ) offset or drift.