AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.15.1 FB1.BISSBITS
General Information
Type NV Parameter
Description
Specifies the number of Biss Sensor (Position) Bits for the BiSS Mode C
encoder in use.
Units bits
Range 0 to 64 bits
Default
Value
32 bits
Data Type Integer
See Also FB1.SELECT , FB1.IDENTIFIED
Start Ver-
sion
M_01-01-00-100 and M_01-01-03-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 280 No 8 bit No M_01-03-00-000
Description
FB1.BISSBITS specifies the number of BiSS sensor (position) bits for the BiSS Mode C
encoder in use. Typically the value is either 26 or 32 for a BiSS Mode C Renishaw encoder. The
required value for this parameter is provided by the feedback device manufacturer for the par-
ticular device being used.
Related Topics
1 Feedback 1