EasyManuals Logo

Kollmorgen AKD Basic User Manual

Kollmorgen AKD Basic
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #183 background imageLoading...
Page #183 background image
AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.6.9 CAP0.PRESELECT, CAP1.PRESELECT
General Information
Type NVParameter
Description Sets the precondition trigger.
Units N/A
Range 0 to 11
Default
Value
0
Data Type U8
See Also CAP0.TRIGGER, CAP1.TRIGGER
Start Version M_01-00-00-000
Fieldbus Index/Subindex
Object Start Ver-
sion
EtherCAT
COE and
CANopen
3460h/9 CAP0.PRESELECT
3460h
/10
CAP1.PRESELECT
M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed?
Object
Start
Version
Modbus
72 CAP0.PRESELECT
No 8 bit No
M_01-
03-00-
000
98 CAP1.PRESELECT
Description
This parameter specifies the input signal for the precondition trigger.
Trigger Source Input Name
0
General Input 1
(X7)
1
General Input 2
(X7)
2
General Input 3
(X7)
3
General Input 4
(X7)
4
General Input 5
(X8)
5
General Input 6
(X7)
6
General Input 7
(X7)
7 RS485 Input 1 (X9)
8 RS485 Input 2 (X9)
9 RS485 Input 3 (X9)
10 Primary Index
183 Kollmorgenâ„¢ | March 30, 2012