AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.4.1 AOUT.CUTOFF
General Information
Type NV Parameter
Description
Sets the analog output low-pass filter cutoff
frequency.
Units Hz
Range 0 to 10,000 Hz
Default
Value
0 Hz
Data Type Float
Start Version M_01-04-01
Description
AOUT.CUTOFF sets the cutoff frequency in Hz for a single-pole low-pass
filter on the Analog Output.
A value of 0 Hz will turn off the filter and will allow all frequencies to pass through.
The filter can be used with all modes of Analog Output.