EasyManua.ls Logo

Kollmorgen AKD Basic

Kollmorgen AKD Basic
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.4.7 AOUT.OFFSET
General Information
Type NV Parameter
Description
Sets the analog input off-
set.
Units V
Range -10 to +10 V
Default
Value
0 V
Data Type Float
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 22 No 16 bit Yes M_01-03-00-000
Description
This parameter sets the analog input offset.
Kollmorgen | March 30, 2012 146

Table of Contents

Related product manuals