Page #372 background image
AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.24.10 MOVE.GOVEL
General Information
Type Command
Description
MOVE.GOVEL moves the motor at a constant speed specified by MOVE.RU-
NSPEED and direction specified by MOVE.DIR.
Units N/A
Range N/A
Default
Value
N/A
Data Type N/A
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 1110 No Command No M_01-05-11-000
Description
MOVE.GOVEL (Go at Velocity) moves the motor at a constant speed specified by MOVE.RU-
NSPEED and direction specified by MOVE.DIR.
The motor speed follows a velocity profile as specified by MOVE.ACC, MOVE.DEC, and
MOVE.RUNSPEED. This profile may be modified during the move using MOVE.GOUPDATE.
Program execution continues with the line immediately following MOVE.GOVEL as soon as
the move is initiated. Program execution does not wait until the move is complete.
The drive must be enabled in order for any motion to take place.
MOVE parameters are only valid when DRV.OPMODE = 3 and
DRV.CMDSOURCE = 5.
Related Topics
MOVE.GOREL | MOVE.GOABS | MOVE.GOVEL | MOVE.GOHOME| Statement Table
Kollmorgenâ„¢ | March 30, 2012 372

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD Basic and is the answer not in the manual?

Kollmorgen AKD Basic Specifications

General IconGeneral
BrandKollmorgen
ModelAKD Basic
CategoryController
LanguageEnglish

Related product manuals